Bituminous Liquid Waterproofing

 

1. SUBSTRATE PREPARATION
– The surface of the underground walls must be stable, clean and free of loose objects. Pins and mourelatos cut within a 3 cm depth are repaired, including any possible concrete nests, using the mortar repair DOMOREPAIR R3.
– Construction joints cementing stops are opened in the form of a V, at a depth of 3 cm and filled with mortar repair DOMOREPAIR R3. In the compound of the floor and the vertical elements, a smoothing gully is created with DOMOREPAIR R4 mortar repair or with a reinforced cement construction resin for higher demands, DOMORESIN SP.

PRIMING

b
Application of a Primer layer elastomeric bituminous aqueous base lacquer SOPRAKOTE, diluted with 50% water. (0,3 L/m2). Alternatively, SOPRAMUR LATEX is proposed.

APPLICATION

b2
Then, two crosswise layers of SOPRAKOTE (0,6 L/m2/layer) are applyied. Alternatively, SORPAMUR LATEX is proposed.

  PROTECTION

g
Placement of the HDPE egg casket, PROTECDRAIN, as a protection of the waterproofing layer from the impending embankment and as a drainage layer. PROTECDRAIN is mechanically bond above the waterproofing sealing with metal support. The earth backfill is recommended to be done step by step.

Read here the technical solution
pdf file